4.03 Operating Set-up

Follow this set-up procedure each time the system is operated:

WARNING

Disconnect primary power at the source before assembling or disassembling power supply, torch parts, torch and

leads assemblies or adding coolant.

A. Coolant Level Inspection

Check the coolant level in the coolant tank at the front of the unit. If the tank is below 3/4 full, add coolant.

B. Torch Parts Selection

Check the torch for proper assembly. Install proper torch parts for the application per the Torch section of the

manual..

C. Input Power

Check the power source for proper input voltage. Close main disconnect switch or plug unit in to supply pri-

mary power to the system.

D. Work Cable Connection

Check for a solid and clean work cable connection to the workpiece or cutting table. The connection area must

be free from paint and rust.

E. Torch Connection

Check that the torch is properly connected.

F. Gas Supplies

Connect desired plasma and shield gases. Make sure gas sources meet requirements. Check connections and

turn gas supply on. Set Gas Selection Switch on rear panel to the correct plasma gas being used.

With H2O Mist option: Select the desired shield gas as follows:

1. If gas shield is desired, set shield selector switch to GAS position.

2. If Water Mist shield is desired, set shield mode selector switch to ‘H

2

O MIST’ position. Water must be con-

nected to the rear panel H

2

O connection.

NOTES

Tap water should only be used for shield gas.

If tap water pressure is over 100 psi (6.9 bar) there must be a Water Regulator (Catalog No. 8-6118) installed
between the water source and the Power Supply.