Auto-cut 200 xt – Tweco 200 XT Auto-Cut 400V User Manual

Page 58

Advertising
background image

AUTO-CUT 200 XT

4-12

OPERATION

Manual 0-5284

Code

Message

Remedy / Comments

249

Inverter 2A Circuit

Fault

Inverter Module 2 Section A detected a circuit fault; Damaged Inverter Module 2

250

Not used

Reserved for other models with additional inverter sections.

251

Not used

Reserved for other models with additional inverter sections.

252

Not used

Reserved for other models with additional inverter sections.

253

Inverter 1A Over

Temp

Inverter Module 1 Section A detected an over temperature fault; Check for restricted air flow,

clogged radiator; Defective fan; If problem persists replace inverter module.

254

Inverter 1B Over

Temp

Inverter Module 1 Section B detected an over temperature fault; Check for restricted air flow,

clogged radiator; Defective fan; If problem persists replace inverter module.

255

Inverter 2A Over

Temp

Inverter Module 2 Section A detected an over temperature fault; Check for restricted air flow,

clogged radiator; Defective fan; If problem persists replace inverter module.

256

Not used

Reserved for other models with additional inverter sections.

257

Not used

Reserved for other models with additional inverter sections.

258

Not used

Reserved for other models with additional inverter sections.

259

Inverter 1A Over

Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce

power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

260

Inverter 1B Over

Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce

power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

261

Inverter 2A Over

Temp Ambient

Inverter circuitry is over temperature likely cause is ambient greater than 40 deg C; Reduce

power supply cutting Duty Cycle; Reduce ambient air temperature; Add auxiliary cooler.

262

Not used

Reserved for other models with additional inverter sections.

263

Not used

Reserved for other models with additional inverter sections.

264

Not used

Reserved for other models with additional inverter sections.

265

Inverter 1A No Input

Power

Inverter section may have no input power. Contactor not closed; Defective contactor or CB4

tripped; Inverter section input not connected; Defective Inverter.

266

Inverter 1B No Input

Power

Inverter section may have no input power. Contactor not closed; Defective contactor or CB4

tripped; Inverter section input not connected; Defective Inverter.

267

Inverter 2A No Input

Power

Inverter section may have no input power. Contactor not closed; Defective contactor or CB4

tripped; Inverter section input not connected; Defective Inverter.

268

Not used

Reserved for other models with additional inverter sections.

269

Not used

Reserved for other models with additional inverter sections.

270

Not used

Reserved for other models with additional inverter sections.

271

Inverter ID reading

fault

CCM found ID values inconsistant during reading. CCM to an Inverter section ribbon dam-

aged or disconnected; Inproper ribbon cable routing.