06 power supply status codes, Power supply status codes -9, Auto-cut 200 xt – Tweco 200 XT Auto-Cut 400V User Manual

Page 55

Advertising
background image

AUTO-CUT 200 XT

Manual 0-5284

OPERATION

4-9

• Normally used with nitrogen.
• Provides very smooth cut surface.
• Reduces smoke and heat input to the workpiece.
• Effective up to 1/2 inch (12.7 mm) maximum material thickness.
• Tap water provides low operating expense.

4.06 Power Supply Status Codes

NOTE

See the Appendix for Advanced Troubleshooting

On start-up and during operation, the power supply control circuitry performs various tests. If the circuitry detects

a condition requiring operator attention, the status display on the front panel shows a 3 digit code preceded by

either letter “E” (currently active fault) or letter “L” (last or latched fault) meaning a fault occurred stopping the

process but is not currently active.

Some conditions can be active indefinitely, while others are momentary. The power supply latches momentary

conditions; some momentary conditions can shut down the system. The indicator may show multiple conditions

in sequence; it is important to recognize all possible conditions that may be displayed.

NOTE

500 codes are not used for this system

CCM Status Code

Group 1 Plasma Process

Code

Message

Remedy / Comments

101

Plasma Disabled

Plasma Enable Off ; External Disable activated or CCM TB1-1&2 jumper missing; 40 circuit

ribbon cable from Relay PCB to CCM disconnected or defective;

102

Pilot Ignition Failure

Pilot did not start within 15 seconds. Torch consumable parts worn? Ensure current control

setting matches consumables; Plasma pressure too high; Defective Arc Starter; Defective

Pilot PCB; defective Inverter section 1A.

103

Lost Pilot

Pilot went out while Start active. Torch consumable parts worn? Ensure current control set-

ting matches consumables; Plasma pressure too high;

104

Transfer Lost

Arc was transferred to work for more than 50 ms and then went out while Start still active. Arc

lost contact with work, run off edge, over hole, etc.; Standoff too high; Ensure current control

setting matches consumables; Wrong gas pressure

105

Not used

Reserved for legacy product

106

Pilot Timeout, no

Transfer

Must transfer from Pilot to Cutting Arc in 0.085 seconds (SW8-1 OFF) or 3 sec. (SW8-1 ON).

Standoff too high or void in work under torch; Current Control setting too low for consumables

resulting in: Pilot current too low for consumables; Wrong gas pressure.

107

Not used

Reserved for legacy product

108

Tip to Electrode

voltage fault.

Tip voltage too close to electrode voltage. Rear panel gas switch set to wrong gas; Torch con-

sumable parts worn out; Wrong consumables installed causing tip to electrode short; Plasma

pressure too low; Leak in Plasma hose to torch; Current Control set too high for consum-

ables; Defective Pilot PCB; Shorted torch body .

109

Not used

Reserved for legacy product

110

Not used

Reserved for legacy product