Auto-cut 200 xt, Simplified cnc circuit, Sw 1 – Tweco 200 XT Auto-Cut 400V User Manual

Page 88: Auto-cut xt ccm simplified cnc & gas control, Sol1, Plasma (51 psi), Sw 2

Advertising
background image

AUTO-CUT 200 XT

A-�

APPENDIX

Manual 0-5284

Simplified CNC Circuit

Art # A-11578

Art # A-11578

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

J26

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

J22

GAS ON

ENABLE

PLAS_ENABLE SW

PLAS_ EN_SW_RET

/ GAS PRESS OK

GND

/ BASIC ID

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

J21

GND

+10V

GND

/ CNC Plasma Enable (+)

/ CNC Plasma Enable (-)

8- COMM Ref (1K Ohm)

4- / CNC Start (-)

6- Divided Arc V (+)

5- Divided Arc V (-)

12- OK to Move (-)

14- OK to Move (+)

7- / Preflow ON (+)

9- / Preflow ON (-)

3- / CNC Start (+)

(121)

(123)

(124)

(125)

(126)

(127)

(129)

(130)

(133)

(137)

(131)

(133)

(104)

(136)

(134)

(135)

(139)

(138)

(134)

(135)

(136)

(137)

(138)

(139)

(140)

(141)

(143)

(142)

(140)

(141)

(142)

(143)

PSR

SPARE #1

J15-1 to chassis used for

SC-11 cable shield

The COMM Ref at pin 8

is also for the SC-11

1

2

3

4

5

6

7

8

9

10

11

12

13

14

J15-CNC

SOL1

PLASMA

SW 1

RUN / SET

PS1

PLASMA (51 PSI)

SOL2

SHIELD

Chassis

AC 24V Ret-GCM2 (B8)

(111)

AC 24V-GCM2 (B8)

(130)

(131)

(123)

(124)

R?

10K

(130)

(127)

(125)

(126)

(128)

CURRENT

CONTROL

+10V (CC Pot Hi)

CC Pot Wiper

CC Pot Low

Div Arc V (+)

Div Arc V (-)

/Start - Stop (+)

/Start - Stop (-)

Stop Mom NC

OK2 (contact)

/ CNC Enable (+)

/ CNC Enable (-)

OK2 (contact)

OK to MOVE (+)

OK to MOVE (-)

PILOT is ON

PILOT is ON

Preflow ON (+)

Preflow ON (-)

Hold Start (-)

Hold Start (+)

/ Plasma Marking (+)

/ Plasma Marking (-)

/ Corner Current Reduction (-)

/ Corner Current Reduction (+)

/ Cut Expanded Metal (-)

/ Cut Expanded Metal (+)

Spare #2 NO

Spare #2 NC

Spare #1b NO

SOL3

H2O Mist

2

1

3

SW 2

(111)

(130)

(164)

(165)

GAS

H2O

H2O Mist Option

Installing H2O Mist Option

------------------------------------------------------------------

Remove #130 from Shield SOL, connect #165 in it's place.

Connect #111 with other #111 on Shield SOL.

Connect #130 from SW2 with other #130 on SW1.

ALL SW OFF f or 50: 1 ( defaul t )

SW12A ( 1) ON = 16. 7: 1 ( SC- 11)

SW12B ( 2) ON = 30: 1

SW12C ( 3) ON = 40: 1

SW12D ( 4) ON = 25: 1

1

8

SW

12

A

VOLTAGE DIVIDER

2

7

SW

12

B

3

6

SW

12

C

4

5

SW

12

D

-

4

+

3

5

B

DC VOLTS

CONTACTS

18 VDC or Contacts

SW6B

SW6A

OK TO MOVE SELECT

+18VDC

OK

J15-13 connects SC-11

chassis to PS chassis.

Auto-Cut XT CCM Simplified CNC & Gas Control

1

2

3

4

5

6

7

8

9

10

11

12

TB1

1

2

3

4

5

6

7

8

9

10

11

12

TB2

1

2

3

4

5

6

7

8

9

10

11

12

TB3

10- Corner Current Reduction (+)

11- Corner Current Reduction (-)

Advertising