SECTION 4: OPERATION

4.01 Power Supply Indicators

Art # A-11467

AC Indicator

Temp Indicator

Gas Indicator

DC Indicator

A/

Status Indicator

A/

AC Power Lamp

Indicates unit has passed the input power tests and AC power is being supplied to the inverter modules via

the input contactor when the ON/OFF switch is in ON position.

TEMP Lamp: Normally OFF. Lamp will come ON when the internal temperature sensors detect temperatures

above normal limits. Let the unit cool before continuing operation.

GAS Lamp: Flashing during start up gas purge/pump priming, then whenever gas is flowing. Indicates ad-

equate gas pressure and coolant flow for operation.

DC Lamp: Indicates the power supply is generating output DC voltage.

A/

Status Indicator: Shows CCM code version on start up followed by the Current Control setting and

system status. Refer to Section 4.05 and Status Code Section for details.

Rear Panel AC Power Lamp

Indicates AC power is present inside the unit