AUTO-CUT 200 XT

Manual 0-5284

OPERATION

4-11

Code

Message

Remedy / Comments

227

Inverter 2A Incom-

patible Revision

Unsupported Inverter Revision; Ribbon cable CCM J33 to Inverter Module 2 Section A dam-

aged; CCM code version incompatible with Inverter revision or model

228

Not used

Reserved for other models with additional inverter sections.

229

Not used

Reserved for other models with additional inverter sections.

230

Not used

Reserved for other models with additional inverter sections.

231

Inverter 1A VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable

CCM J31 to Inverter Module 1 Section B damaged or loose; Wrong voltage Inverter Module 1

installed; Defective Inverter module

232

Inverter 1B VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable

CCM J32 to Inverter Module 1 Section B damaged or loose; Wrong voltage Inverter Module 1

installed; Defective Inverter module

233

Inverter 2A VAC

Mismatch

Inverter AC Voltage rating incompatible with Power Supply voltage rating; Ribbon cable

CCM J33 to Inverter Module 2 Section A damaged or loose; Wrong voltage Inverter Module 2

installed; Defective Inverter module

234

Not used

Reserved for other models with additional inverter sections.

235

Not used

Reserved for other models with additional inverter sections.

236

Not used

Reserved for other models with additional inverter sections.

237

Too Few Inverters

Found

Two or more Inverter Sections required to operate; Ribbon cable from CCM to Inverter Section

damaged or disconnected;

238

BIAS VAC Invalid

Invalid AC Voltage Selection; Damaged or loose connection at J61 of System Bias Supply

239

AC Voltage High

System Bias PCB detected AC Voltage is higher than Power Supply rated Voltage; System

Bias Supply J61 Voltage Selection connection damaged or disconnected; Defective System

Bias PCB; Defective CCM

240

AC Voltage Low

System Bias PCB detected AC Voltage is lower than Power Supply rated Voltage; System

Bias Supply J61 Voltage Selection connection damaged or disconnected; Defective System

Bias PCB; Defective CCM

241

Inverter 1A Input

Voltage Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter

Module 1 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or open connec-

tion between input terminals and W1 contactor or contactor and input of Inverter Section;

Defective Inverter module

242

Inverter 1B Input

Voltage Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter

Module 1 Section B; Poor AC Power Quality; Defective W1 contactor; Loose or open connec-

tion between input terminals and W1 contactor or contactor and input of Inverter Section;

Defective Inverter module

243

Inverter 2A Input

Voltage Error

Inverter Input Voltage fault; voltage out of range or missing phase at AC Input of Inverter

Module 2 Section A; Poor AC Power Quality; Defective W1 contactor; Loose or open connec-

tion between input terminals and W1 contactor or contactor and input of Inverter Section;

Defective Inverter module

244

Not used

Reserved for other models with additional inverter sections.

245

Not used

Reserved for other models with additional inverter sections.

246

Not used

Reserved for other models with additional inverter sections.

247

Inverter 1A Circuit

Fault

Inverter Module 1 Section A detected a circuit fault; Damaged Inverter Module 1

248

Inverter 1B Circuit

Fault

Inverter Module 1 Section B detected a circuit fault; Damaged Inverter Module 1