11 connect torch leads to the arc starter, Connect torch leads to the arc starter -12, Auto-cut 200 xt – Tweco 200 XT Auto-Cut 400V User Manual

Page 36

Advertising
background image

AUTO-CUT 200 XT

3-12

INSTALLATION

Manual 0-5284

3.11 Connect Torch Leads to the Arc Starter

1. Remove the top cover.

2. Pass the torch leads and coolant leads through the torch leads port on the back of the module. Ensure that the

leads outer jacket slides into the port.

CAUTION

Use protective gloves when handling the leads. Do not kink or bend the leads.

3. Inside the module, slide the leads clamp over the leads but do not secure until all leads have been connected.

4. Connect the leads to the module in the sequence shown. Coolant leads and connectors are color-tagged; red

for coolant return, green for coolant supply. Shield gas and plasma gas connections are left- and right- hand

threaded and will not interchange.

Art # A-11528

1

Torch Leads: Coolant Supply & Return
Plasma Gas
Shield Gas
Outer Leads Shield

3

Clamp * (Clamp type may vary)

2