05 primary power connections, Primary power connections -4, Auto-cut 200 xt – Tweco 200 XT Auto-Cut 400V User Manual

Page 28: Connect input power and system ground cables, Input power

Advertising
background image

AUTO-CUT 200 XT

3-4

INSTALLATION

Manual 0-5284

3.05 Primary Power Connections

The primary power cable and through hole cable grip must be supplied by the end user and connected to the power

supply. Refer to local and national electrical codes for suggested cable and fuse sizes.

Connect Input Power and System Ground Cables

1. Remove the input power cover to the right of the coolant filter at the rear of the power supply. To do this

remove the two screws then lift up and pull away.

2. Carefully cut back the outer sheath on the primary input power cable to expose the individual wires. Cut

back the insulation on the individual wires. Route the cable upward through Input Power Port at the bottom

of the panel. There are 2 extra plates included at the cable entrance. Discarding one or both allows changing

the opening size for larger cable/strain relief.

J15 - CNC

CB4 - 5A 120 VAC

F1 - 8A SB 230 VAC

F2 - 8A SB 230 VAC

CB3 - 5A 24 VAC

CB2 - 5A 120 VAC

USER INPUT

HEIGHT CONTROL

AIR / O2

PLASMA

N2 / H35

PLASMA

Input Power

Art # A-11949

Advertising