Warning – Wheatheart X160 Series User Manual

Page 75

Advertising
background image

W

HEATHEART

- G

RAIN

A

UGERS

3. A

SSEMBLY

X160-85, X160-105, X160-125

30875 R0

75

Important:

The X160-85 model requires four 5/16” cable clamps (19333) per cable, and the

X160-105/125 models require four 1/2” cable clamps (20606) per cable.

4. Tie up excess ends of lift cable with tape or cable ties.

Important:

Lift cables will stretch with initial use. Check and adjust frequently.

Figure 3.29 Connecting the Lift Cylinder Cables

WARNING

Ensure that cable clamps are positioned with

the U-bolt portion of the clamp on the

unloaded side of the lift cables (see Figure

3.29).
Tighten 1/2” cable clamp nuts to 60 ft-lbs, and

5/16” cable clamp nuts to 35 ft-lbs, as

measured by a recently and accurately

calibrated torque wrench.
Failure to tighten the nuts properly could

cause the main auger tube to drop from a

raised position quickly and without warning,

and could lead to personal injury or death.

85’ MODEL

105/125’ MODELS

Advertising