Notice – Wheatheart X160 Series User Manual

Page 98

Advertising
background image

3. A

SSEMBLY

W

HEATHEART

- G

RAIN

A

UGERS

X160-85, X160-105, X160-125

98

30875 R0

Figure 3.52 Electric Motor Wiring

6. Route the electrical cable over top of the boot, using existing upper hose

catches.

7. Uncoil the longer electrical cable from the receiver box. Identify the positive

and negative wires by referring to Figures 3.52 and 3.53. The positive wire

has a circuit breaker and printing on it.

8. Attach the positive wire directly to the positive terminal on the tractor battery

and the negative wire to the tractor chassis as shown in Figure 3.53. The

negative terminal on the tractor battery should also be grounded to the

chassis. There are 5/16” lugged terminals supplied with the kit.

POSITIVE

WIRE WITH

RED BOOT

CONNECTS TO

POSITIVE MOTOR

TERMINAL.

SHORT ELECTRICAL CABLE

CONNECTS TO ELECTRIC

MOTOR ON POWER SWING.

ELECTRIC MOTOR

NEGATIVE WIRE CONNECTS TO

NEGATIVE MOTOR TERMINAL.

LONG ELECTRICAL CABLE

CONNECTS TO TRACTOR

CHASSIS AND BATTERY.

POSITIVE WIRE WITH

CIRCUIT BREAKER

CONNECTS TO POSITIVE

BATTERY TERMINAL.

NEGATIVE WIRE

CONNECTS TO

TRACTOR CHASSIS.

NOTICE

If these electrical cables are not hooked up properly the

electric controller will be damaged.

Advertising