Install towers, Dimensions, Lateral tower location (figure 17) – Great Plains 3N4010HDA Predelivery Manual User Manual
Page 22: Tower inlet angle (figure 17), Tower height (figure 18), Bf l r
20
3N-4010HDA and ADC2350B
Great Plains Manufacturing, Inc.
196-444Q
10/10/2008
Install Towers
Dimensions
Refer to Figure 17, Figure 18 and Figure 19 on page 21
All lateral measurements are from outside end of tubes
to centerline of mount location. Tower placement on right
wing is a mirror image of left wing.
Lateral Tower Location (Figure 17)
Figure 17
Tower Placement, Left Wing
27235
3
2
1
b
c
a
B
F
L
R
Tower
No.
Location
Name
for Row Spacing
7.5in (19cm) 10in (25cm)
1, 6 Wing, Outside
50in (127cm)
40in (100cm)
2, 5 Wing, Inside
40in (100cm)
40in (100cm)
3, 4 Center
Center in Slot
Tower
No.
Location
Name
Inlet Angle
1, 6
Wing, Outside
to drill center
2, 5
Wing, Inside
front, 45
°
toward center
3, 4
Center
to rear
1
2
3
a
b
c
Tower
No.
Location
Name
Height and Reference
1, 6 Wing, Outside
33in (83.8cm)
to top of 4x2in tube
2, 5 Wing, Inside
35in (88.9cm)
to top of 4x2in tube
3, 4 Center
33in (83.8cm)
above tube slot reinforcing ring
x
y
z