Install wsmb harnesses, Interconnect wsmb section harnesses, Ud r l – Great Plains 3N4010HDA Predelivery Manual User Manual
Page 36

34
3N-4010HDA and ADC2350B
Great Plains Manufacturing, Inc.
196-444Q
10/10/2008
Install WSMB Harnesses
Start with tower 1 (left wing, left tower)
110. Select one:
467981201 INT AG HARNESS, WSMB MOD-
ULE
Join the row harness connector
connector on the row harness
.
Plug the WSMB connectors
.
These connectors are not interchangeable, and are
keyed to ensure correct insertion.
111. Select two:
800-082C CABLE TIE .31X21.5 6DIA 120LB
Coil up excess row harness leads and tie the bundle
to the tower, above and below the lower U-bolt.
112. Repeat step 110 and step 111 for each tower.
Interconnect WSMB Section Harnesses
Start with the left wing.
113. At the left wing WSMB harnesses
, interconnect
the female (receptacle) of left (outer) CAN bus
with
the male (plug) end of the mid-wing CAN bus.
Also connect the
power receptacle and plug
Note: The unconnected mid-wing CAN bus connector, at
right (near drill center) must be a receptacle.
114. At drill center, interconnect the center WSMB har-
nesses as shown in Figure 44, so that the free end
of the CAN bus at right is a receptacle
115. At the right wing, interconnect the wing WSMB har-
nesses as shown in Figure 44, so that the free end
of the CAN bus at right is a receptacle
Figure 43
WSMB Harness
28200
98
1
2
94
93
98
97
3
4
5
U
D
R
L
98
1
94
97
83
Figure 44
Left Wing Interconnect
28201
98
U
D
R
L
98
98
3
3