Set parameter levels – Great Plains ADC2220 Operator Manual User Manual

Page 125

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Appendix C - Vintage Carts

121

2012-10-17

Table of Contents

Index

167-073M

Pin blockage sensors do not need to be disconnected
and are not requested during initial monitor setup. If
system is equipped with pin style blockage sensors
press the ACK button to skip FLOW 1-7. The blockage
module package includes installation instructions.

When optical blockage sensors have been supplied, you
must plug the 3-pin connector of the blockage module in
order as requested by the module; FLOW 1-7. The
Optical blockage sensors may be plugged into the proper
2-pin blockage harness connection during initial setup.

Set Parameter Levels
All parameters must be set before the unit is ready to
use.You can adjust alarm trip points, sensor
configurations and other system features. Set these
parameters when you initially set up the system. You can
re-adjust them later. Parameter settings are stored in
monitor memory even when monitor power is shut off.

a.

Choose the function you wish to program by
pressing the up and down buttons until desired
function is displayed on the monitor readout.

b.

Hold MODE button to enter programming mode.

c.

Use the MODE button to switch between the
parameters. Each function has several parameters
which can be adjusted. The top display indicates
which parameter is being adjusted. The lower display
indicates how the parameter is currently set.

d.

Use the following chart to program the parameters.
The chart lists the parameters for each function and
proper parameter settings.

e.

Use the up and down buttons to increase or
decrease the parameter level to the proper setting.

Note: To disable a function, set the pulse level to zero.

The system does not monitor disabled functions.

f.

When you have properly set all parameters for the
function, press MODE button until “SAVE” is on the
top display.

g.

Press the up button to choose yes (Y) if you wish to
save settings. Press the down button for no (N).

h.

Hold down the ACK button. If yes was chosen, the
unit beeps five times before saving the settings.

i.

Repeat steps a. through h. for each function until all
parameters have been set.

Function Monitored

Monitor Display

Proper Setting

Parameter Descr.

Parameter Range

Ground Speed

PPM

30-foot drill: 2986
34-foot drill: 3337
35-foot drill: 3337
40-foot drill: 3912
45-foot drill: 4372

Pulses per mile

500 to 9999

Fan Speed

PULSES

3

Hits per revolution

1 to 10

LO FAN

2000

Low rpm alarm point

1000 to 9900

HI FAN

5000

High rpm alarm point

low alarm to 9900

Metering Shafts

Repeat for front and rear

PULSES

2

Hits per revolution

1 to 4

Bin Level

LEVEL

20%

Low bin alarm point

0 to 100%

Field and Total Area

Set WIDTH and UNITS
for both functions.

WIDTH

35 ft.

Implement width

0 to 99 ft.

UNITS

Operator
preference

Units values are
displayed in

English or Metric

Flow (Pin Sensors)

BOXES

Proper setting is
the total number of
modules attached

Number of blockage
modules–may not be one
per tower, often is not.

0 to 16

TYPE

Zero

0 to 63

Flow (Optical
Sensors)

INSTALL “Y”

Proper setting is
the total number of
sensors attached to
each module

Number of sensors per
module

0 to 16

INSTALL “N”

Operator
Preference

Turns row sensors “on”
and “off”

ON or OFF

Advertising