92

ADC2220

Table of Contents

Index

Great Plains Manufacturing, Inc.

167-073M

Table of Contents

Index

2012-10-17

No Seed Flow
at One or
Several Rows

Plugged seed hose

See page 93.

Plugged opener seed tube

Lift up drill, expose bottom of seed tube and
clean out.

Debris in tower distribution ring.

Remove tower cap and clear debris.

Air leaks, resulting in low seed flow, then seed
hose plugging

Check hopper lids, meter seals, manifold caps
and seed hose connections. Adjust latch and/or
replace seals as needed.

Fan speed too low, resulting in low seed flow,
then seed hose plugging

See “Recommended Fan Speeds” on page 74.

Fan won’t run fast enough, resulting in low
seed flow, then seed hose plugging

Tractor must be able to supply 18 gallons/minute
at 2000 psi.

Check that hydraulic fan check valve is not
installed backward.

Obstruction in meter

Empty hopper and clean out meter. Have
strainer in place for all operations. Always clean
out residual materials after planting.

Hydraulic fan running in reverse, resulting in
low seed flow, then seed hose plugging

Check hydraulic circuit flow direction.

Meter sprocket damaged

Replace seed cup sprocket.

No Seed Flow,
All Rows

Clutch switch off in tractor cab

Turn clutch switch on.

Implement lift switch out of adjustment or failed. Check, adjust or replace switch. See implement

Operator Manual.

Chain broken or removed

Inventory chains against routing diagrams.

Gearbox clutch disengaged

Check gearbox clutches engaged and pinned.

Electric clutch failed

Replace clutch. On an emergency basis, use
the clutch lock-up procedure on page 74.

Clutch circuit failed

Replace failed component or cable. On an
emergency basis, use the clutch lock-up
procedure on page 74.

Clutch circuit fuse open

Correct problem leading to blown fuse and
replace fuse. On an emergency basis, use the
clutch lock-up procedure on page 74.

Sprocket loose on shaft

Check all sprocket pins, keys and set screws.

Insufficient fan airflow

Check Magnehelic gauge with fan running.
Check for sufficient oil reserve and flow.
On early carts, check fan pressure switch.
Switch should close at 800 psi and higher.

Problem