50
ADC2220
Great Plains Manufacturing, Inc.
167-073M
2012-10-17
Special Start-up
Refer to Figure 56
A special start-up screen appears when the monitor is
turned on in the following circumstances:
1.
The monitor has been learned but is unplugged from
the drill.
2.
The monitor has been learned but has lost its
memory.
3.
The monitor has not been learned.
• System Start-up: Selected for “Normal Operation”.
The last used system configuration and settings are
loaded.
• Learn New System: Special start-up used to learn all
new sensors while keeping the previous system
settings.
• Default Settings: Special start-up used to reset all
sensor settings to their default setting.
• Learn New System and Default Settings: Complete
reset of the monitor. Removes all learned sensors and
restores all the default sensor settings.
If this screen appears and you are unsure of what to do
contact your Great Plains dealer.
Learn New System
The learn mode is a one time process that identifies
each sensor with the monitor.
Figure 56
Special Start-Up Screen
29045