Blockage Module Settings

Refer to Figure 77
The Blockage Module Settings only affect those systems
with Blockage Sensors (single sided sensor detecting
seed flow only). A blockage module is a box mounted to
the frame of the drill that blockage sensors are
connected to.

Note: If the menu shows

Number of Modules 0,

this indicates that there are no blockage modules
or sensors being used with the current system.

Runs per Module Setup
The Runs per Module setting adjusts the number of
Blockage Sensors connected to the selected module.

The factory default is:

16

Individual Runs Setup
The Individual Runs Setup allows you turn specific
blockage sensors on (Enable) and off (Disable).

The factory default is:

Enabled (all rows are on)

Blockage Module Test
The Blockage Module Test is used to check
communication between monitor and modules.

Blockage Calibration
A blockage calibration must be done for proper operation
of the blockage sensors. This procedure should be done
when changing seed rates or seed varieties, such as
from Soybeans to Wheat.

Blockage Calibration Procedure:

Refer to Figure 78
1.

Enter Blockage Calibration mode by highlighting
Blockage Calibration and pressing the SELECT
softkey.