Great Plains Mfg., Inc.

Hook Up for Carts Y1078 and Later

1.

Connect blue-coded lift hoses to tractor outlets. Lift
hoses are 3/8-inch hoses that go directly to couplers C
and D on rear of cart.

2.

Connect orange-coded auger hoses to tractor outlets.
Auger hoses go to the diverter valve on the inside of
the left tongue rail.

3.

Connect yellow-coded fan hoses to tractor outlets. If
your tractor has a priority circuit for hydraulic motors,
connect fan hoses to this circuit.

a.

Hook fan hose under extended-cylinder symbol to
the outlet you choose to be the pressure side of
circuit. The pressure hose (1) runs out of the se-
lector valve. See Figure 1-3.

b.

Hook fan hose under retracted-cylinder symbol to
other outlet.

NOTE: Fan hoses are not the same size. A 1/2-inch and a
3/8-inch hose are paired together.

Figure 1-3

Hydraulic Hook-Up for Carts Y1078 and Later

4.

Connect decaled sump hose to the tractor hydraulic
reservoir. Refer to your tractor operator’s manual for
instructions. The sump hose (2) runs beside the cart
fan. See Figure 1-3.

NOTE: For proper hydraulic flow, use a poppet-style, Pio-
neer quick coupler to connect sump hose to tractor. See
Figure 1-4.

IMPORTANT: For CTA implements, some tractors re-
quire an auxiliary flow kit to prevent damage to the hy-
draulic pump. Contact a service technician who is
factory trained on your tractor before hooking to cart
and CTA implement.

1

2

17172

IMPORTANT: Failure to properly plumb sump hose into
tractor hydraulic reservoir may result in tractor or drill
damage.

Figure 1-4

Poppet-Style Coupler for Sump Hose

Hook Up for Carts Y1077 and Earlier

For Use with NTA Implements
1.

Connect lift hoses. Lift hoses are 3/8-inch hoses that
go directly to lift couplers on rear of cart.

2.

Connect auger hoses. Auger hoses go to the diverter
valve on inside of tongue rail.

3.

Connect fan hoses. If your tractor has a priority circuit
for hydraulic motors, connect hoses to this circuit.

a.

Hook 1/2-inch hose (1) shown in Figure 1-5 to the
outlet you choose to be the pressure side of cir-
cuit.

b.

Hook 3/8-inch hose to other outlet.

NOTE: Fan hoses are not the same size. A 1/2-inch and a
3/8-inch hose are paired together.

Figure 1-5

Hydraulic Hook-Up for Older Carts with NTA

c.

Connect 1/2-inch sump hose (2) shown in Figure
1-5
to the tractor hydraulic reservoir. Refer to your
tractor operator’s manual for instructions.

NOTE: For proper hydraulic flow, use a poppet-style, Pio-
neer quick coupler to connect sump hose to tractor. See
Figure 1-4.

17646

1

2

16444

IMPORTANT: Failure to properly plumb sump hose into
tractor hydraulic reservoir may result in tractor or drill
damage.