Overall
Low
Population,
cont.

Pass gaps too large

Check marker extension (page 114).
For GPS, check planter size programmed.

Actual field size is different

Population may be correct, and calculations are not.

Seed monitor reporting excess area

Readings can vary with conditions (wheel slippage,
and effective rolling radius in soft soils) and planting
patterns.

Low
Population,
Single Row

Shutter opening too narrow - starving meter
of seed (low seed pool)

Adjust shutter to higher setting.

Meter starvation due to bridging at shutter

Re-adjust for shutter bridging (page 56).
If seed is treated, increase seed lubricant.

Meter starvation due to blockage above inlet Clear blockage (page 56).

Meter starvation due to bridging above inlet,
caused by high levels of seed treatment

Clear bridge (page 56). Increase seed lubricant.

Incorrect seed disk on one row

Install correct seed disk.

Chain skipping at row unit.

Check chain, idler and sprocket condition.

Skips due to low meter pressurization at one
or several rows

Check shutter setting. Check for excess wear on seed
drop brush. Check for loose or leaking pressure hose.

Skips due to skipping chain

Check for worn chain, worn idlers, low chain slack
(page 82) and failed meter bearing.

Skips due to debris in disk pockets

Remove rain covers. Inspect and clean out disks.

Row has blank disk installed

Replace with seeding disk.

Seed tube plugged

Raise planter, expose bottom of seed tube and clean
out.

Low or
Erratic
Seed Flow

Seed meter plugged, due to operation with
fan shut off, or manifold pressure too low.

Close shutters. Clean-out meters. Set fan for correct
manifold pressure. Resume planting.

Population Too Low

Problem

Cause

Solution

Population Too High

Problem

Cause

Solution

Overall High
Population

Incorrect seed rate

Check seed rate charts

Two seeds per pocket on the disk
(doubles), due to excess meter
pressurization

Methodically decrease the meter pressurization.
See “Fan and Adjustment” on page 43.

Two seeds per pocket on the disk
(doubles), due to pockets too large for
the seed

Select a disk with smaller pockets.

The meter pressurization is too high, as
confirmed by gauge

Reduce fan speed or increase butterfly valve setting.

Air meter pressure too high due to
pressure sensor not zeroed properly.

Re-zero the gauge with the fan off.