Electric clutch operation, Electric clutch lockup – Great Plains YP1625A Operator Manual User Manual

Page 42

Advertising
background image

38

YP1125A & YP1625A

Table of Contents

Index

Great Plains Manufacturing, Inc.

401-625M

Table of Contents

Index

2013-08-13

Electric Clutch Operation

Refer to Figure 46, which depicts the left planter side on and
the right side shut off.
Electric clutches allow for turning planting off while the
planter is lowered. When the planter is raised, clutches
are always

a

off, due to the lift switch.

A clutch for each drive shaft allows for independent
control of each side of the planter. The clutches are
controlled via the CFM “CLUTCH” switches.

For regular field operation, turn “MASTER”

, “Left”

and “Right”

clutch switches to the “ON” position. This

activates the magnet on each clutch and allow clutch
shafts to rotate.

To shut off planting on one or both sides to
accommodate point row while planter is lowered, switch
either to “OFF” position. Turning the MASTER switch off
disengages both sides. If the planter has hydraulic meter
drive, MASTER off also shuts down the drive motor.

Electric Clutch Lockup

Refer to Figure 47
In case of electric clutch failure, electric clutches can be
locked in the engaged mode using metric bolts stored in
the brace plate above each clutch.

1.

Remove rubber plugs

from oil shield

to gain

access to bolts

.

2.

Align cutouts at bolt holes

.

3.

Insert M8-1.25

×14 mm long metric bolts .

Note: Use only 14 mm length bolts as provided or

machine damage can occur. Longer bolts will
damage the clutch. Shorter bolts may not effect a
lock-up.

4.

If you observe half the hole obstructed by a metal
disc

, you are not at a cutout.

5.

Replace oil shield plugs.

If the entire hole is obstructed by a metal disc

, you are

not at a cutout.

When at a cutout, the bolt will screw in with minimal
resistance until the bolt head reaches the clutch face.

Clutch Slippage Risk:
Keep oil shield and oil shield plugs in place. Do not allow
lubricant to enter the clutch when lubricating the planter.
If clutches slip, operate with clutch lock-up until overhaul or
replacement of clutches.

a. On planters with hydraulic drive, the seed monitor overrides the lift switch during “FILL DISK” and “5 REV TEST” operations.

Figure 46

CFM: Point Row

28490

1

2

3

1

2

3

Figure 47

Electric Clutch Lockup

29329

4

3

2

1

1

2

3

4

3

Figure 48

Clutch Plate Nearly at Cutout

26168

5

4

5

5

Advertising
This manual is related to the following products: