Meter brush replacement, Tufted brush replacement, Strip brush replacement – Great Plains YP1625A Operator Manual User Manual

Page 99: Seed drop brush replacement

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Maintenance and Lubrication

95

2013-08-13

Table of Contents

Index

401-625M

Meter Brush Replacement

Consult the Parts manual (401-625P) for current
replacement part numbers.

Refer to Figure 119
Tufted Brush Replacement
1.

Remove and save both 10-24 hex head cap
screws

and nylock nuts (not shown).

2.

Remove the tufted brush assembly

, and replace

with new assembly.

3.

Re-insert the 10-24 screws, and re-start the nylock
nuts. Carefully tighten each nut just until plate has no
play under the screw heads.

4.

Add a half turn to the nuts. Do not tighten fasteners
to normal 10-24 torque, or the plate may fracture.

Strip Brush Replacement
Note: Do not loosen or remove any of the three

5

16

-18

cap screws

retaining the brush holder.

1.

Insert the flat blade of a large screwdriver into the
slots of the brush holder snaps

. Turn each snap

clockwise to release brush holder

.

2.

Prepare to catch drop brush

(which will fall lose).

Slide brush holder left and up to free front edge from
under washer

. Remove brush holder.

3.

Remove used strip brushes from the holder by
sliding them downward out of the grooves.

Refer to Figure 120
4.

Insert replacement strip brushes into grooves at
holder bottom so that notched ends

are at the

bottom.

Refer to Figure 119
5.

Check strip brush positioning with a trial re-insertion
of the brush holder. The ends of the long brush must
fit snugly into meter housing grooves at top

and

lower rear

. The bottom end of the short brush

must fit snugly in the lower front housing groove

.

If any significant force is require to re-seat the brush
holder, a strip brush is likely too high or too low.

6.

Relax the position of the brush holder, re-position the
drop brush (see below), and re-seat the brush
holder.

7.

Starting with the bottom snap, swing snaps

back

into engagement.

Seed Drop Brush Replacement

Refer to Figure 119
1.

Insert the flat blade of a large screwdriver into the
slots of the brush holder snaps

. Turn each snap

clockwise to release brush holder

.

2.

Prepare to catch drop brush

(which will fall lose).

Slide brush holder left and up. Remove drop brush.

3.

Position new drop brush so that it is flat against back
of meter housing, and under ridges on leading edge
of brush holder.

4.

Slide holder forward/down to engage drop brush.
Swing lower, then upper snap into engagement.

13

14

16

11

13

17

19

12

15

Figure 119

Brush Replacement

29719

21

20

11

12

15

13

14

Figure 120

Strip Brush Notches

29720

18

18

16

17

18

19

20

20

13

13

14

16

Advertising