1, 2, 3, or more outlets fail.

Outlets can be side-by-side or random.
Plugging may also move from one
outlet to another.

Foreign matter in seed chamber in
bottom of airbox.

Clean out seed chamber.

Little or no seed to a lot of rows with
heavily treated seed.

Seed treatment sticky.

Add Ezee Glide Plus to seed to dry out
seed treatment.

Treatment mixed unevenly and
plugging outlets.

Clean out seed. Re-mix.

Seed Delivery Troubleshooting

Problem

Cause

Solution

General Troubleshooting

Problem

Cause

Solution

Population
Alarms

See “Population Troubleshooting Charts” on page 79.

Excess Seed
Remaining

See “Population Troubleshooting Charts” on page 79.

Field size different.

After ruling out population problems, re-check geography.

Excessive gaps between planter
passes.

Adjust marker, page 56.

Seed

Consumptio

n Too High

See “Population Troubleshooting Charts” on page 79.

Field size different.

After ruling out population problems, re-check geography.

Excessive overlap.
Irregular shaped field.

Adjust marker, page 56.

Rows Not

Planted

If not detected by seed monitor,
check for plugged row-unit seed tube

Lift planter, expose bottom of seed tube and clean out.

Uneven
seed
spacing

See “Population Troubleshooting Charts” on page 79.

Excessive field speed.

Reduce field speed.

Unclean seed.

Use clean seed.

Damaged seed tube

Inspect; repair or replace.

Seed-Lok

®

plugging.

Lock up Seed-Lok

®

, page 74.

Row-unit discs not turning.

See “Row-unit discs not turning freely.” in this
Troubleshooting chart.

Plugged row-unit seed tube.

Lift up planter, expose bottom of seed tube and clean out.

Worn/rusted sprockets and/or chain
idler or bearings.

Check and replace any worn/rusted sprockets or chain idlers.

Lack of proper seed lubrication on
seed.

See “Seed Lubricant” on page 111.

Planter does
not fold or
unfold fully

Fold cylinders out of phase

Re-phase cylinders, refer to page 27

Air in lines

Bleed fold circuit, refer to page 97

Advertising