Meter adjustments, Meter rain cover, Seed inlet shutter adjustment – Great Plains YP1625A Operator Manual User Manual

Page 72: Meter rain cover seed inlet shutter adjustment, 05 | ii iii

Advertising
background image

68

YP1125A & YP1625A

Table of Contents

Index

Great Plains Manufacturing, Inc.

401-625M

Table of Contents

Index

2013-08-13

Meter Adjustments

There are adjustments for seed inlet, and choice of disks.
There are no other adjustments, in particular no brush
adjustments, at the meter.

Meter Rain Cover
The rain cover keeps side winds from unseating seed in
disk pockets. It also keeps precipitation, sunlight and
field debris out of the meters.

Refer to Figure 86
To remove the rain cover, peel the flexible snap latches,
at top

and rear

, away from the meter housing. Pivot

the cover forward and down at tab

in slot.

When removing a cover, inspect it for damage and
missing parts. If a cover does not have both latches, and
an intact edge seal under the latches, the cover is apt to
be lost during transport or field operations.

To replace a latch, temporarily remove the seal near the
latch. Slide the replacement latch onto the cover lugs
from the meter side, then snap the other end down over
the lugs. Re-install the seal.

Seed Inlet Shutter Adjustment

Refer to Figure 87 (showing the shutter at setting 3)
The seed inlet shutter regulates the volume of bulk seed
presented to the seed disk. The operating settings vary
with crop, seed size and treatments. The shutter also has
settings for row shut-off (completely closed), and
clean-out (wide open).

The Seed Rate Charts include suggested initial shutter
settings. Refine these settings based on experience, and
on inspection of the slope of the seed pool at the bottom
of the seed disk.

The shutter is operated by a handle. Lift the handle away
from the meter plate. Move the handle to half a setting
higher than the new setting, then back to the new setting,
and lower the pawl into that slot.

The table at right is a general summary of shutter
settings.

Figure 86

Rain Cover Removal

29606

1

2

3

1

2

3

Figure 87

Seed Inlet Shutter

29607

0

5

|

II

III

||||

Setting

Setting Typically Used For

Top (0)

Closed: Row Shut-Off, Meter Re-Fill

| (1)

Small seeds, such as Milo, with little or

no treatments

|| (2)

Small treated seeds and edible beans

(such as Soybeans)

||| (3)

Corn, round popcorn

|||| (4)

Large corn, or heavily treated corn

Bottom (5)

Wide Open: Clean-Out

Advertising
This manual is related to the following products: