Marker operation – Great Plains YP1625A Operator Manual User Manual

Page 48

Advertising
background image

44

YP1125A & YP1625A

Table of Contents

Index

Great Plains Manufacturing, Inc.

401-625M

Table of Contents

Index

2013-08-13

Marker Operation

Electrocution Hazard:
Check for overhead lines before operating markers. If a
marker contacts an electrical line, all metal parts of the
planter and tractor can have lethal voltages present. There
may be no indication of this condition until a person completes
the circuit to ground. At higher voltages, electrocution can
occur without direct contact.

Before operating markers, make sure they are properly
bled as described in “Bleeding Hydraulics” on page 97.

For markers to operate, the marker hydraulic circuit must
be enabled:

Refer to Figure 52
1.

On the CFM switch panel, set the “Marker/Fold”
switch

to Marker. Leave this switch in “Marker”

position for all field operations. It also acts to lock the
folding system when in “Marker”.

Refer to Figure 53
2.

If the planter is equipped with an auxiliary hydraulic
system, set the selector valve

(found near the

sequence valve

at the marker base on the left

wing) to “Marker”.

Dual markers are equipped with a sequence valve

to

control lift sequence. Starting with both markers up, the
sequence is:

1.

Activate tractor hydraulic lever; right marker lowers
while left marker stays up.

2.

Reverse hydraulic lever; right marker raises while left
marker stays up.

3.

Activate hydraulic lever; left marker lowers while right
marker stays up.

4.

Reverse hydraulic lever; left marker raises while right
marker stays up.

5.

Pattern repeats.

Folding speed of dual markers is adjusted with
adjustment screws on sequence valve body. Because
excessive folding speed may damage markers, adjust
markers to a safe folding speed according to “Marker
Adjustments
” on page 56.

Note: To get both markers in the lowered position at the

same time, activate hydraulic lever to lower one
marker. After marker is lowered, move lever to
opposite position then quickly reverse lever and
hold until other marker is lowered.

Figure 52

CFM: Markers Enabled

28491

1

1

2

3

Figure 53

Aux Valve Set to Markers

28493

2

3

3

Advertising
This manual is related to the following products: