Great Plains Manufacturing, Inc.

Table of Contents

Index

Adjustments

59

2013-08-13

Table of Contents

Index

401-625M

Frame-Mounted Coulters

Refer to Figure 67
At the shaft

, adjust the coulter depth for a running

depth

of 4 to 4

1

2

inches (10.2 to 11.4 cm) below

ground level if off row, if on row as a no-till coulter
operate at planting depth only

. Refer to the Vantage I

manual (204-376M) for further adjustments.

Do not adjust the spring

tension. It is factory pre-set.

Vantage I Applicator

Refer to Figure 68
At the back plate

, adjust the tine height for a running

depth

of 1 inch (2.5 cm) below ground level

. Refer

to the Vantage I manual (204-376M) for further
adjustments.

Figure 67

Frame-Mount Coulter

25392

1

4

3

2

1

2

3

4

Figure 68

Vantage I Applicator

22951

5

3

6

5

6

3

Advertising