Seed too
shallow or
scattered on
ground from a
single row

Bottom of seed tube damaged.

Replace seed tube. Avoid setting planter straight down. Use
forward motion when lowering.

Row not penetrating in tire tracks. Increase down force on parallel arm springs.

Opener depth too shallow.

Change side depth wheel setting.

Twin Rows
were timed
but became
out of time.

Timing will change when a
population change has been
made.

Re-time meters from the population based timing chart.

Chain has jumped.

Check sprockets and chain for excessive wear or rusty stuck
links.

System is
unable to
automatically
control air
meter
pressure.

Signal from air pressure sensor
lost. (failed sensor or wiring)

Air pressure may be controlled manually, consult
DICKEY-john

®

Planter/Drill Control manual, User Level 2/3.

Population Related

Problem

Cause

Solution

Seed Delivery Troubleshooting

Problem

Cause

Solution

Single row doesn’t fill or keep up with
other rows.

Y tube is bent/angled off feed
pipe.

Loosen pipe and spin so the bend is
straight down and Y-tube is not
pointing to front or rear of air pipe.

Drop tube to meter is too long,
causing seed to pool and plug
hose or Y-tube.

Shorten hose (with planter raised, but
row units lowered, to ensure hose is
not too short).

Both rows on one meter outlet low or
not keeping up with other rows.

Blockage in air slot in top of
airbox.

Clear by using a long skinny tool and
taking hose off through hose outlet.

It may be necessary to take top off
airbox or use side access doors to
clear junk from slot.

Bad hose routing between
delivery hose and airbox on wing.

Correct hose routing.

Multiple rows fail for lack of seed.

Fan speed too high/too low.

Check/adjust fan speed.

Out of seed.

Add seed.

Single or multiple hoses plugging just
ahead of airbox.

Fan speed too high/too low.

Check/adjust fan speed.

Possible air leak.

Check for air leak downstream
between box and top of meter.

All rows fail.

Lack of seed.

Fan speed too high. Adjust fan speed.

Extremely high populations may
require slightly reduced field speed.

Advertising