Dell PowerEdge R905 User Manual

Page 22

Advertising
background image

22

About Your System

Table 1-7.

LCD Status Messages

Line 1
Message

Line 2
Message

Causes

Corrective Actions

N/A

SYSTEM NAME

A 62-character string that
can be defined by the user
in the System Setup
program.

The SYSTEM NAME
displays under the
following conditions:

• The system is powered

on.

• The power is off and

active POST errors are
displayed.

This message is for
information only.

You can change the
system string in the
System Setup program.
See "Using the System
Setup Program" on
page 45.

E1000

FAILSAFE,

Call Support

See "Getting Help" on
page 181.

E1114

Temp Ambient

Ambient system
temperature is out of
acceptable range.

See "Troubleshooting
System Cooling
Problems" on page 157.

E1210

CMOS Batt

CMOS battery is missing,
or the voltage is out of
acceptable range.

See "Troubleshooting the
System Battery" on
page 155.

E1211

ROMB Batt

RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.

Reseat the RAID battery.
See "Installing the SAS
RAID Controller Card
Battery" on page 115, and
"Troubleshooting System
Cooling Problems" on
page 157.

E12

nn

# PwrGd

Specified voltage
regulator has failed.

See "Getting Help" on
page 181.

E1229

CPU # VCORE

Processor # VCORE
voltage regulator has
failed.

See "Getting Help" on
page 181.

Advertising