Dell PowerEdge R905 User Manual

Page 37

Advertising
background image

About Your System

37

Memory address

line failure at

address, read

value expecting

value

Faulty or improperly
installed memory
modules.

See "Troubleshooting
System Memory" on
page 158.

Memory double word

logic failure at

address, read

value expecting

value

Memory odd/even

logic failure at

address, read

value expecting

value

Memory write/read

failure at

address, read

value expecting

value

Memory tests

terminated by

keystroke.

POST memory test
terminated by pressing
the spacebar.

Information only.

No boot device

available

Faulty or missing optical
drive subsystem, hard
drive, or hard-drive
subsystem, or no boot
disk in drive A.

Use a bootable diskette,
CD, or hard drive. If the
problem persists, see
"Troubleshooting an
Optical Drive" on page 160,
and "Troubleshooting a
Hard Drive" on page 161.
See "Using the System
Setup Program" on page 45
for information about
setting the order of boot
devices.

Table 1-8.

System Messages (continued)

Message

Causes

Corrective Actions

Advertising