28

About Your System

E1812

HDD ##

Removed

Specified hard drive has
been removed from the
system.

Information only.

E1914

DRAC5 Conn2

Cbl

DRAC 5 cable is missing
or unseated.

Reconnect the cable. See
"RAC Card" on page 86.

E1A14

SAS Cable A

SAS cable A is unseated,
missing, or bad.

Check the cable
connection to the SAS
backplane. See "SAS
Backplane Board
Connectors" on page 178.

E1A15

SAS Cable B

SAS cable B is unseated,
missing, or bad.

Check the cable
connection to the SAS
backplane. See "SAS
Backplane Board
Connectors" on page 178.

E1A1C

LOM Mezz

Missing

NIC daughter card is
missing.

Install or reseat the NIC
daughter card.

E2010

No Memory

No memory is installed in
the system.

Install memory modules.
See "System Memory" on
page 94.

E2011

Mem Config

Err

Memory detected, but is
not configurable. Error
detected during memory
configuration.

Check the memory
configuration and
reinstall the memory
modules if necessary. See
"System Memory" on
page 94.

See "Troubleshooting
System Memory" on
page 158.

E2012

Unusable

Memory

Memory is configured,
but not usable. Memory
subsystem failure.

See "Troubleshooting
System Memory" on
page 158.

Table 1-7.

LCD Status Messages (continued)

Line 1
Message

Line 2
Message

Causes

Corrective Actions

Advertising