Dell PowerEdge R905 User Manual

Page 24

Advertising
background image

24

About Your System

E1313

Fan

Redundancy

One or more cooling fans
has failed. Cooling fan
redundancy has been lost.

See "Troubleshooting
System Cooling
Problems" on page 157.

E1414

CPU #

Thermtrip

Specified microprocessor
is out of acceptable
temperature range and
has halted operation.

See "Troubleshooting
System Cooling
Problems" on page 157. If
the problem persists,
ensure that the
microprocessor heat sinks
are properly installed. See
"Troubleshooting the
Microprocessors" on
page 167.

NOTE:

The LCD continues

to display this message
until the system’s power
cord is disconnected and
reconnected to the AC
power source, or the SEL
is cleared using either
Server Assistant or the
BMC Management Utility.
See the Dell OpenManage
Baseboard Management
Controller User’s Guide for
information about these
utilities.

E1418

CPU #

Presence

Specified processor is
missing or bad, or the
system is in an
unsupported
configuration.

See "Troubleshooting the
Microprocessors" on
page 167.

Table 1-7.

LCD Status Messages (continued)

Line 1
Message

Line 2
Message

Causes

Corrective Actions