35

CPUs with

different cache

sizes detected!

Microprocessors with
different cache sizes are
installed.

Ensure that all
microprocessors have the
same cache size and that
they are properly installed.
See "Processors" on
page 100.

Decreasing

available memory

Faulty or improperly
installed memory
modules.

See "Troubleshooting
System Memory" on
page 158.

Error: Incorrect

memory

configuration

CPU

n

The DIMM group for
CPU n is incorrectly
configured and caused
the system to halt.

See "General Memory
Module Installation
Guidelines" on page 94 for
memory configuration
information. If the problem
persists, see
"Troubleshooting System
Memory" on page 158.

!*** Error: Remote

Access Controller

initialization

failure *** RAC

virtual USB

devices may not be

available...

Remote Access Controller
initialization failure

Ensure that the Remote
Access Controller is
properly installed. See
"Installing an Optional
RAC Card" on page 86.

Gate A20 failure

Faulty keyboard
controller; faulty system
board.

See "Getting Help" on
page 181.

General failure

The operating system is
unable to carry out the
command.

This message is usually
followed by specific
information. Note the
information and take the
appropriate action to
resolve the problem.

Table 1-8.

System Messages (continued)

Message

Causes

Corrective Actions

Advertising