Dell PowerVault 735N (Rackmount NAS Appliance) User Manual

Page 34

Advertising
background image

Codes and Error Messages: Dell PowerVault 735N Systems Service Manual

file:///C:/Users/Phebega_Pericho/Desktop/spv735N/en/sm/beep.htm[3/15/2013 4:18:15 PM]

correction
code(ECC) on
disk read

Controller has
failed

subsystem or hard-disk drive
subsystem (defective system
board)

CD-ROM drive
not found

Improperly connected or
missing CD-ROM drive

Check that the diskette drive/CD-ROM drive unit
is seated properly against the interposer board on
the peripheral cage. See "

Drives

."

CPUs with
different level
2 cache sizes
detected

Two different types of
microprocessors are installed

Install a correct version of the

microprocessor

so

both microprocessors have the same level 2
cache size.

Data error

Faulty diskette, diskette drive,
or hard-disk drive

Replace the diskette, diskette drive, or hard-disk
drive.

Decreasing
available

memory

One or more DIMMs
improperly seated or faulty

Remove and reseat the DIMMs

. If the problem

persists,

replace the DIMMs

.

Diskette drive
0 seek failure

Diskette drive
1 seek failure

Faulty or improperly inserted
diskette, incorrect
configuration settings in
System Setup program, loose
diskette/tape drive interface
cable, or loose power cable

Check that the diskette drive/CD-ROM drive unit
is properly against the interposer board on the
peripheral cage. Run the System Setup program
to correct the diskette drive type. See "

Using the

System Setup Program

." Check the drive

interface and power cables.

Diskette read
failure

Faulty diskette, faulty or
improperly connected
diskette/tape drive interface
cable, or loose power cable

Check that the diskette drive/CD-ROM drive unit
is properly against the interposer board on the
peripheral cage. See "

Drives

." Replace the

diskette-drive interface cable.

Diskette
subsystem reset
failed

Faulty diskette/tape drive
controller (defective system
board)

Replace the system board

.

Diskette write

protected

Diskette write-protect feature
activated

Move the write-protect tab on the diskette.

Drive not ready

Diskette missing from or
improperly inserted in diskette
drive

Reinsert or replace the diskette.

Embedded server
management
error

Embedded server
management is
not present

Embedded server
management memory may be
temporarily corrupted

Shut down the system to clear the memory, and
then restart the system.

Gate A20
failure

Faulty keyboard controller
(defective system board)

Replace the system board

.

General failure

Operating system corrupted or
not installed properly

Reinstall the operating system.

Advertising