Removing and Replacing Parts: Dell PowerVault 735N Systems Service Manual

file:///C:/Users/Phebega_Pericho/Desktop/spv735N/en/sm/remove.htm[3/15/2013 4:18:18 PM]

To remove a SCSI backplane board, perform the following steps.

NOTICE: See "

Protecting Against Electrostatic Discharge

" for information on protecting the system from electrostatic discharge.

1.

Remove the optional plastic bezel

(if installed).

2. If you have not already done so,

unlock and open the system doors

and

remove the hard-disk drive locks

from the hard-disk drive bays

(see

Figure 10

).

3.

Remove the fan assembly

.

NOTICE: You must remove all hard-disk drives to gain access to the SCSI daughter card and to enable the removal of the SCSI
backplane board.

4. Unlatch and pull all four hard-disk drives from the hard-disk drive bay. Label the drives with their location in the hard-disk drive bay.

5. Remove the SCSI backplane daughter card by opening the retention lever on each card's front edge and pulling the daughter card out of

its socket on the SCSI backplane (see

Figure 15

).

When installing a replacement SCSI backplane board, see

Figure 16

for cable connections.

NOTICE: To prevent your system from overheating, make sure the SCSI cables do not block the cooling fans.

Figure 15. Removing the SCSI Daughter Card

1 SCSI backplane board

2 SCSI backplane daughter cards

3 Retention lever

6. Record the connectors used and disconnect all SCSI cables attached to the SCSI backplane board (see

Figure 16

).

DC power connector (POWER2) is connected to the power input connector on the backplane board.

NOTICE: To prevent your system from overheating, make sure the SCSI cables do not block the cooling fans.

Figure 16. SCSI Backplane Connectors

1 Thumbscrew

2 Data interface cable to system

board (BACKPLANE)

3 Power cable to PSDB (P2)

4 Ultra3 SCSI cable to

PERC 2/DC

Advertising