Removing an iDRAC6 Enterprise Card

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.

1 Turn off the system, including any attached peripherals, and disconnect

the system from the electrical outlet.

2 If present, disconnect the Ethernet cable from the iDRAC6 enterprise card

connector on the system back panel. See Figure 1-3.

3 Open the system. See "Opening the System" on page 66.
4 Remove the cooling shroud. See "Removing the Cooling Shroud" on

page 68.

5 Remove the VFlash media card (if installed) from the iDRAC6 enterprise

card. See "Removing a VFlash Media Card" on page 106.

6 Pull back slightly on the two tabs at the front edge of the card and gently

lift the front edge of the card from the retention standoffs.
As the card releases from the standoffs, the connector under the card

disengages from the system board connector.

7 Slide the card away from the back of the system until the RJ-45 connector

is clear of the back panel, then lift the card out of the system.

8 Replace the plastic filler plug over the port at the system back panel.

See "Back-Panel Features and Indicators" on page 16 for the location

of the port.

9 Replace the cooling shroud. See "Installing the Cooling Shroud" on

page 69.

10 Close the system. See "Closing the System" on page 67.
11 Reconnect the system and peripherals to their power sources, and turn

them on.