Dell PowerVault NX3100 User Manual

Page 33

Advertising
background image

About Your System

33

Sector not found.

Seek error.

Seek operation

failed.

Faulty hard drive, USB

device, or USB medium.

Replace the USB medium or

device. Ensure that the USB

or SAS backplane cables are

properly connected. See

"Troubleshooting a USB

Device" on page 130 or

"Troubleshooting a Hard

Drive" on page 140 for the

appropriate drive(s) installed

in your system.

Shutdown

failure.

General system error.

See "Getting Help" on

page 157.

Sparing mode

disabled. For

sparing mode,

matched sets

of three must

be populated

across slots.

The memory configuration

does not match the setting

in BIOS. The BIOS setting

has been disabled.

Reconfigure the memory

modules for Memory

Sparing mode. See "System

Memory" on page 82.

The amount of

system memory has

changed.

Memory has been added or

removed or a memory

module may be faulty.

If memory has been added or

removed, this message is

informative and can be

ignored. If memory has not

been added or removed,

check the SEL to determine

if single-bit or multi-bit

errors were detected and

replace the faulty memory

module.

See "Troubleshooting

System Memory" on

page 137.

Message

Causes

Corrective Actions

Advertising