Dell PowerVault NX3100 User Manual

Page 24

Advertising
background image

24

About Your System

Alert! iDRAC6 not

responding.

Rebooting.

The optional iDRAC6 is not

responding to BIOS

communication either

because it is not functioning

properly or has not

completed initialization.

The system reboots.

Wait for the system

to reboot.

Alert! iDRAC6 not

responding.

Power required

may exceed PSU

wattage.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The optional iDRAC6

has hung.
The optional iDRAC6 was

remotely reset while

system was booting.
After AC recovery, the

optional iDRAC6 takes

longer than normal to boot.

Remove AC power to the

system for 10 seconds and

restart the system.

Alert! Node

Interleaving

disabled! Memory

configuration

does not support

Node

Interleaving.

The memory configuration

does not support node

interleaving, or the

configuration has changed

(for example, a memory

module has failed) so that

node interleaving cannot be

supported. The system still

runs, but without node

interleaving.

Ensure that the memory

modules are installed in a

configuration that supports

node interleaving.

Check other system

messages for additional

information for possible

causes. For memory

configuration information,

see "General Memory

Module

Installation Guidelines" on

page 83. If the problem

persists,

see "Troubleshooting System

Memory" on page 137.

Message

Causes

Corrective Actions

Advertising