28

About Your System

DIMM

configuration on

each CPU should

match.

Invalid memory

configuration on a

dual-processor system.

The memory module

configuration for each

processor must be identical.

Ensure that the memory

modules are installed in a

valid configuration.

See "General Memory

Module

Installation Guidelines" on

page 83.

Embedded NICx and

NICy:

OS NIC=<ENABLED

|DISABLED>,

Management

Shared NIC=

<ENABLED

|DISABLED>

The OS NIC interface is set

in BIOS. The Management

Shared NIC interface is set

in management tools.

Check the system

management software or the

System Setup program for

NIC settings. If a problem is

indicated, see

"Troubleshooting a NIC" on

page 131.

Error 8602 -

Auxiliary Device

Failure. Verify

that mouse and

keyboard are

securely

attached to

correct

connectors.

Mouse or keyboard cable is

loose or improperly

connected.

Reseat the mouse or

keyboard cable.

Defective mouse or keyboard. Ensure that the mouse or

keyboard is operational.

See "Troubleshooting a USB

Device" on page 130.

Gate A20 failure.

Faulty keyboard controller;

faulty system board.

See "Getting Help" on

page 157.

Invalid

configuration

information -

please run SETUP

program.

An invalid system

configuration caused a

system halt.

Run the System Setup

program and review the

current settings. See "Using

the System Setup Program

and UEFI Boot Manager" on

page 41.

Invalid PCIe card

found in the

Internal_Storage

slot!

The system halted because

an invalid PCIe expansion

card is installed in the

dedicated storage controller

slot.

Remove the PCIe expansion

card and install the

integrated storage controller

in the dedicated slot. See

"RAID Battery (Optional)"

on page 115.

Message

Causes

Corrective Actions

Advertising