Troubleshooting system memory, E "troubleshooting system, See "troubleshooting system – Dell PowerVault NX3100 User Manual

Page 137: Troubleshooting system, Troubleshooting, System memory" on, E "troubleshooting

Advertising
background image

Troubleshooting Your System

137

6 If the fan does not function, turn off the system and install a new fan.

See "Replacing a Cooling Fan" on page 79.

7 Restart the system.

If the problem is resolved, close the system. See "Closing the System" on

page 67.
If the replacement fan does not operate, see "Getting Help" on page 157.

Troubleshooting System Memory

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.

NOTE:

Invalid memory configurations can cause your system to halt at startup

without video output. See "General Memory Module Installation Guidelines" on

page 83 and verify that your memory configuration complies with all

applicable guidelines.

1 If the system is operational, run the appropriate online diagnostic test.

See "Using Online Diagnostics" on page 147.
If diagnostics indicates a fault, follow the corrective actions provided

by the diagnostic program.

2 If the system is not operational, turn off the system and attached

peripherals, and unplug the system from the power source. Wait at least

10 seconds and then reconnect the system to power.

3 Turn on the system and attached peripherals and note the messages

on the screen.
Go to step 14 if an error message appears indicating a fault with a

specific memory module.

4 Enter the System Setup program and check the system memory setting.

See "Memory Settings Screen" on page 45. Make any changes to the

memory settings, if needed.
If the memory settings match the installed memory but a problem is still

indicated, go to step 14.

Advertising