About Your System

E1712

PCI SERR B##

D## F##

PCI SERR Slot

#

The system BIOS has
reported a PCI system
error on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.

The system BIOS has
reported a PCI system
error on a component that
resides in the specified
slot.

Remove and reseat the
PCI expansion cards. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 149.

Reinstall the expansion-
card cage. See "Expansion-
Card Cage" on page 91.

If the problem persists, the
riser card or system board
is faulty. See "Getting
Help" on page 167.

E1714

Unknown Err

The system BIOS has
determined that there has
been an error in the
system, but is unable to
determine its origin.

See "Getting Help" on
page 167.

E171F

PCIE Fatal

Err B## D##

F##

PCIE Fatal

Err Slot #

The system BIOS has
reported a PCIe fatal error
on a component that
resides in PCI
configuration space at bus
##, device ##, function
##.

The system BIOS has
reported a PCIe fatal error
on a component that
resides in the specified
slot.

Remove and reseat the
PCI expansion cards. If the
problem persists, see
"Troubleshooting
Expansion Cards" on
page 149.

Reinstall the expansion-
card cage. See "Expansion-
Card Cage" on page 91.

If the problem persists, the
riser card or system board
is faulty. See "Getting
Help" on page 167.

E1810

HDD ## Fault

The SAS subsystem has
determined that hard drive
## has experienced a
fault.

See "Troubleshooting a
Hard Drive" on page 146.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions