Removing the power supply blank, Installing the power supply blank, System fans – Dell PowerVault DL2000 User Manual

Page 78: Removing a system fan

Advertising
background image

78

Installing System Components

Removing the Power Supply Blank

Using a Phillips screwdriver, remove the screw on the left side of the blank,
rotate the blank slightly to clear the bay, and remove from the chassis.

NOTICE:

To ensure proper system cooling, the power supply blank must be

installed on the unoccupied power supply bay in a non-redundant configuration.
Remove the power supply blank only if you are installing a second power supply.

Installing the Power Supply Blank

To install the power supply blank, insert the tab on the right edge of the blank
into the slot in the power supply bay wall. Rotate the blank into the power
supply bay and secure with the Phillips screw.

System Fans

The system includes four hot-pluggable cooling fans.

Removing a System Fan

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.

NOTICE:

The system fans are hot-pluggable. To maintain proper cooling while the

system is on, replace only one fan at a time.

1 Open the system. See "Opening the System" on page 67.

CAUTION:

Use caution when handling the fan until the fan blades stop spinning.

2 Raise the fan handle and pull the fan straight up from the fan cage to clear

the chassis. See Figure 3-8.

Book.book Page 78 Monday, September 14, 2009 12:57 PM