Dell PowerVault DL2000 User Manual

Page 29

Advertising
background image

About Your System

29

E201E

POST Mem Test

BIOS POST memory test
failure.

See "Troubleshooting
System Memory" on
page 142. If problem
persists, see "Getting Help"
on page 167.

E201F

DRAC Config

Dell remote access
controller (DRAC)
configuration failure.

Check screen for specific
error messages.

Ensure that DRAC cables
and connectors are
properly seated. If problem
persists, see your DRAC
documentation.

E2020

CPU Config

CPU configuration failure. Check screen for specific

error messages.

E2021

Memory

Population

Incorrect memory
configuration. Memory
population order incorrect.

Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 142.

E2022

POST Fail

General failure after video. Check screen for specific

error messages.

E2110

MBE Crd #

DIMM ## & ##

One of the DIMMs in the
set implicated by "## &
##" has had a memory
multi-bit error (MBE). If
no memory card is present,
the "Crd #" string is left
out of the message.

See "Troubleshooting
System Memory" on
page 142.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions

Book.book Page 29 Monday, September 14, 2009 12:57 PM