30

About Your System

E2111

SBE Log

Disable Crd #

DIMM ##

The system BIOS has
disabled memory single-bit
error (SBE) logging, and
will not resume logging
further SBEs until the
system is rebooted. "##"
represents the DIMM
implicated by the BIOS. If
no memory riser card is
present, the "Crd #" string
is left out of the message.

See "Troubleshooting
System Memory" on
page 142.

E2112

Mem Spare Crd

# DIMM ##

The system BIOS has
spared the memory
because it has determined
that the memory had too
many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS. If
no memory card is present,
the "Crd #" string is left
out of the message.

See "Troubleshooting
System Memory" on
page 142.

E2113

Mem Mirror

Crd # DIMM ##

& ##

The system BIOS has
disabled memory
mirroring because it has
determined that one half
of the mirror has had too
many errors. "## & ##"
represents the DIMM pair
implicated by the BIOS. If
no memory card is present,
the "Crd #" string is left
out of the message.

See "Troubleshooting
System Memory" on
page 142.

E2118

Fatal NB Mem

CRC

One of the connections in
the Fully Buffered DIMM
(FBD) memory subsystem
link on the Northbound
side has failed.

See "Troubleshooting
System Memory" on
page 142.

Table 1-6.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions