Installing System Components

Power Supplies

Your system supports one or two power supplies rated at an output of 750 W.
If only one power supply is installed, it must be installed in the left power
supply bay (1). If two power supplies are installed, the second power supply
serves as a redundant, hot-plug power source.

NOTICE:

To ensure proper system cooling, the power supply blank must be

installed on the unoccupied power supply bay in a non-redundant configuration.
See "Installing the Power Supply Blank" on page 78.

Removing a Power Supply

NOTICE:

The system requires one power supply for the system to operate normally.

The system is in the redundant mode when two power supplies are installed and
both power supplies are connected to an AC power source. Remove and replace
only one power supply at a time in a system that is powered on. Operating the
system with only one power supply installed and without a power supply blank
installed for extended periods of time can cause the system to overheat.

NOTICE:

If only one power supply is installed, it must be installed in the left power

supply bay (1).

NOTICE:

If you connect the system to a power source in the range of 120 to 220

VAC, and if two power supplies are installed, the second power supply serves as a
redundant, hot-plug power source.

NOTE:

On your rack system, you may have to unlatch and lift the cable

management arm if it interferes with power supply removal. For information about
the cable management arm, see the system’s

Rack Installation Guide.

1 If your system has a single power supply, turn off the system and all

attached peripherals. For a redundant system, you can leave the system
running and proceed to the next step.

2 Disconnect the power cable from the power source.
3 Disconnect the power cable from the power supply and remove the cable

from the cable retention bracket.

4 Release the locking tab on the left side of the power supply by pressing in

toward the right, and rotate the power-supply handle up until the power
supply is released from the chassis. See Figure 3-7.

5 Pull the power supply straight out to clear the chassis.