About Your System

Read fault

Requested sector

not found

The operating system
cannot read from the
diskette or hard drive, the
system could not find a
particular sector on the
disk, or the requested
sector is defective.

Replace the diskette. Ensure
that the diskette and hard
drive cables are properly
connected. See
"Troubleshooting a USB
Device" on page 134, or
"Troubleshooting a Hard
Drive" on page 146 for the
appropriate drive(s)
installed in your system.

Remote

configuration

update attempt

failed

System unable to process
Remote Configuration
request

Retry Remote
Configuration.

ROM bad checksum =

address

Expansion card improperly
installed or faulty.

Reseat the expansion
card(s). Ensure that all
appropriate cables are
securely connected to the
expansion card(s). If the
problem persists, see
"Troubleshooting Expansion
Cards" on page 149.

Sector not found

Seek error

Seek operation

failed

Faulty diskette or hard
drive.

See "Troubleshooting an
Optical Drive" on page 143,
"Troubleshooting a USB
Device" on page 134, or
"Troubleshooting a Hard
Drive" on page 146 for the
appropriate drive(s)
installed in your system.

Shutdown failure

Shutdown test failure.

See "Troubleshooting
System Memory" on
page 142.

Table 1-7.

System Messages (continued)

Message

Causes

Corrective Actions