11

Sensor in and Alarm pinhole:

The signal from the sensor (i.e., infrared sensors, smoke detectors, proximity sensors, door
sensors, etc.) is being transmitted to the unit and this triggers the system to respond and send
signal to relay device (i.e., alarm, telephone etc).

Pin #

Definition

11

Sensor 1 signal

12

Sensor 1 Ground signal

13

Sensor 2 signal

14

Sensor 2 Ground signal

15

Sensor 3 signal

16

Sensor 3 Ground signal

17

Sensor 4 signal

18

Sensor 4 Ground signal

19

Relay signal

20

Relay signal

RS-485 pinhole:

When connect PTZ camera through RS485 interface, please refer to the following pin definition to

connect the DVR and PTZ.

Pin #

DVR site

PTZ site

TX+

RS485 TX+ signal

RS485 RX+ signal

TX-

RS485 TX- signal

RS485 RX- signal

RX+

RS485 RX+ signal

RS485 TX+ signal

RX-

RS485 RX- signal

RS485 TX- signal

i

If user uses the 2 wires for the PTZ camera connection, please connect to the RS-485 TX+ and TX- of the

DVR site.