AVer MOB1304-NET User Manual

Page 54

Advertising
background image

48

OSD MENU

Description

FAN ON
FAN OFF

TEMPERATURE SETUP

TEMP. TYPE

ALARM THRESHOLD

050
040
060/005

HDD STOP

070/005

RESET TO DEFAULT

C

ALARM THRESHOLD
Set the temperature high/low limit (0~100°C/55 ~ 95°C) to prevent
DVR unit overheating/overcooling. When DVR unit temperature
reaches the high/low limit, the system will show the warning message
or send out alarm if the alarm is connected and set.

HDD STOP

Set a specific temperature high/low limit (70 ~100°C /55 ~ 95°C) for
HDD shutdown. When the hard disk temperature reaches the
temperature limit, the HDD will shutdown.

RESET TO DEFAULT

Set all configurations back to factory default.

EVENT SETUP

ALARM SETTING
SENSOR SETTING
MOTION DETECTION
TEMPERATURE
SHOCK DETECTION
VOLTAGE

SHOCK DETECTION SETUP

Set the sensitivity level for vehicle slope detection.

SHOCK DETECTION SETUP

SENSITIVITY
RESET TO DEFAULT

6

SENSTIVITY

Set the sensitivity level of the shock detection.

RESET TO DEFAULT

Set all configurations back to factory default.

EVENT SETUP

ALARM SETTING
SENSOR SETTING
MOTION DETECTION
TEMPERATURE
SHOCK DETECTION
VOLTAGE

VOLTAGE SETUP

RTC(3V) DETECTION
SHOUTDOWN SYSTEM

VOLTAGE SETUP

12V DETECTION

12V DETECTION

Enable/disable voltage detection of total power supply of DVR
system.

RTC(3V) DETECTION

Enable/disable voltage detection for RTC(real time clock).

SHOUTDOWN SYSTEM

Enable/disable to shutdown system when the voltage threshold
reaches the limit.