AVer MOB1304-NET User Manual

Page 87

Advertising
background image

81

Set a specific temperature limit for fan active. When the hard disk temperature reaches
temperature limit, the fan will be active.

- FAN OFF

Set a specific temperature limit for fan stop. When the hard disk temperature drop to the
temperature low limit, the fan will switch to off if the fan was on.

- Alarm Threshold(High)

Set the temperature high limit (0 ~100°C) to prevent DVR unit overheating. When DVR
unit temperature reaches the high limit, the system will show the warning message or
send out alarm if the alarm is connected and set.

- Alarm Threshold(Low)

Set the temperature low limit (55 ~ 95°C) to prevent DVR unit overcooling. When DVR unit
temperature reaches the low limit, the system will show the warning message or send out
alarm if the alarm is connected and set.

- HDD Stop(High)

Set a specific temperature high (0 ~100°C) for HDD shutdown. When the hard disk
temperature reaches the temperature limit, the HDD will shutdown.

- HDD Stop(Low)

Set a specific temperature low limit (55 ~ 95°C) for HDD shutdown. When the hard disk
temperature reaches the temperature limit, the HDD will shutdown.

(8) Shock Detection
Set the value for vehicle slope detection. Click Reset to Default will back to factory default value.
(9) Voltage

- 12V Detection

Enable/disable to detect voltage for total power supply of DVR system.

- RTC(3V) Detection

Enable/disable to detect for RTC (real time clock).

- Shutdown

Enable/disable to shutdown system when the voltage threshold reaches the limit.

- Reset to Default

Set all configurations back to factory default.

Advertising