6.4

Restore the (factory) default parameters

Via the “Parameters Reset” procedure it is possible to bring back the system parameters to the default value. The

procedure can only be activated with machine in OFF mode

Enter the Installer ->Various Parameters -> Default menu and press the ENTER key.

Set the PH99 parameter to “YES”(1) and wait until it becomes “NO”(0) again on the display. The system automatically

restores all parameters’ default values.

Note: After this operation switch OFF and back ON power supply to the board to prevent for

malfunctioning.

6.5

Last maintenance operation date

From the Installer->Maintenance menu, press RIGHT until reaching the following mask:

Positioning the cursor on the “Update” writing and pushing the Enter key the old date relevant for the previous

maintenance will be overwritten with the present date updating the PM90 parameter.