CDR-5000 Functions

4. End of Charging/Discharging

[End of charging at DX]

Alarm buzzer will beep as soon as charging at DX is over. And "FINISHED DX CHARGE" screen will
be shown. The red LED of "DX Charging" is turned off. Charging process is now completed.

*If the "BUZZER" is set to "OFF" in the "INITIAL SETTING", there will be no alarm buzzer.

<How to return to "DX DATA" screen>

Push "Data" key to return to "DX DATA"
screen from "FINISHED DX CHARGE"
screen.

CUTOFF BY

This is show the item that is detected at first among the items related to CHARGE CUT in the "SET-
UP" screen.

*DELTA PEAK (0 DELTA VOLT.): When DELTA PEAK was used for CHARGE CUT.
*TEMP: When battery temperature was used for CHARGE CUT.
*VOLT: When the maximum voltage was used for CHARGE CUT.
*CAPA: When charging capacity was used for CHARGE CUT.
*LOW DC 12V: When the voltages drop of a power source was used as a parameter for CHARGE CUT.

POWER LEVEL

This is the number that represents the status of a battery under charging by calculating from the voltage
drop of the battery to which a certain constant load is applied. The bigger the number is, the better the
condition of the battery is. Take into consideration this number as a guide for daily maintenance of
batteries. The maximum is 120%.

FINISHING BATTERY TEMP

This shows the temperature of a battery when the charging of the battery is completed.