CDR-5000 Functions

Over Current Protection

Although the values of charging and discharging current can be set in the "SET-UP" screen, the actual
current during charging or discharging a battery will be limited in accordance with the voltage mea-
sured at the battery terminals by the "Over Current Protection" of CDR-5000.

[Charging current limit at DX]

Although the value of charging current at DX can be set at 0.1A to 12A in the "SET-UP" screen, the
actual charging current will vary depending on a battery voltage measured at its terminals.

18V or less

: 12A Max

27V or less

: 8A Max

36V or less

: 6A Max

43V or less

: 5A Max

54V or less

: 4A Max

62V or less

: 3A Max

[Discharging current limit at DX]

Although the value of discharging current at DX can be set at 0.1A to 40A in the "SET-UP" screen, the
actual discharging current will vary depending on a battery voltage measured at its terminals.

2.4V or less

: smaller than 40A

7.5V or less

: 40A Max

8.5V or less

: 35A Max

10V or less

: 30A Max

12V or less

: 25A Max

15V or less

: 20A Max

20V or less

: 15A Max

30V or less

: 10A Max

40V or less

: 7.5A Max

50V or less

: 6A Max

60V or less

: 5A Max

greater than 60V : 4A Max

[Charging current limit at TX/RX]

The value of charging current at TX/RX can be set at 0.05A to 2A in the "SET-UP" screen, and the
actual charging current will be nearly equal to the set value regardless of a battery voltage measured at
its terminals.

[Discharging current limit at TX/RX]

Although the value of discharging current at TX/RX can be set at 0.1A to 5A in the "SET-UP" screen,
the actual discharging current will vary depending on a battery voltage measured at its terminals.

10V or less

: 5A Max

greater than 10V : 3A Max