Cino FA470 User Manual
Page 119

Command Descriptions
2-104
Parameter(s)
< Table 6-1-1 > Set TS Operation Parameter(s) Field (Continued)
Parameter / PID / Size
Options
Descriptions
Data Transmission Packet
PID : 02h 04h
Size : 00h 01h (1 Byte)
- 00h
- 01h
Disable *
Enable
UPC/EAN Security Level
PID : 02h 06h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
Level 0
Level 1 *
Level 2
Supplement Scan Voting
PID : 02h 08h
Size : 00h 01h (1 Byte)
- 00h
- 06h
- 08h
- 0Ah
- 0Ch
- 0Eh
- 10h
- 12h
- 14h
- 16h
- 18h
- 1Ah
- 1Ch
- 1Eh
None
Level 1
Level 2
Level 3 *
Level 4
Level 5
Level 6
Level 7
Level 8
Level 9
Level 10
Level 11
Level 12
Level 13
Laser Aiming Control
PID : 02h 09h
Size : 00h 01h (1 Byte)
- 00h
- 01h
(See Notes)
Disable
Enable *
LED Illumination
PID : 02h 0Bh
Size : 00h 01h (1 Byte)
- 00h
- 01h
(See Notes)
Always on
Intelligent Scanning *
Illumination Delay Duration
PID : 02h 0Ch
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 03h
- 04h
(See Notes)
100ms
200ms
300ms
400ms
500ms
Operation Mode
(Tethered Scanner)
PID : 10h 00h
Size : 00h 01h (1 Byte)
- 00h
- 01h
- 02h
- 04h
- 05h
- 06h
- 07h
- 08h
- 09h
(See Notes)
Trigger mode (External triggering) *
Force mode (Continued power on)
Presentation mode (Auto detection)
Level mode (Auto power off)
Diagnostic mode (Test reading)
Alternative mode (Periodic power off)
Toggle mode (Repeat reading)
Flash mode (Pulse driven reading)
Low Power mode (Low Power triggering)
.
Notes
1.
LED Illumination, Illumination Delay Duration are only available for L680, L688, L780, L788
2.
Laser Aiming Control is only available for L688, L788